to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/IR_920-55-R_6-10-inch_IOM_English-1.pdf
external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used). . once the valve is fully isolated vent pressure from the body and cover by loosening a plug or a fitting. . open the stud nuts
and remove the actuator as one unit from the valve body. disassemble necessary control tubs. . disassemble the actuator and examine its parts carefully for signs of wear, corrosion, or any other abnormal conditions. . replace worn parts and all the elastomers. lubricate the bolts and studs threads with...
https://www.bermad.com/wp-content/uploads/WW_730-M5_IOM_English.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used). . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the stud nuts
one unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve actuator assembly for each size. this allows minimum system field work and system down time. . disassemble the actuator and examine its parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/WW_820-PA_IOM_English.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-123-50.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-123-54-X.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-130-50.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-130-55-X.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-130-55.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-423-50-R.pdf
to locate leaks and external damages . functional inspection including: closing, opening and regulation. . close upstream and downstream isolating valves (and external operating pressure when used) . once the valve is fully isolated vent pressure by loosening a plug or a fitting. . open the screw nuts
unit from the valve body. disassemble necessary control tubs. . it is highly recommended to stock a reserve parts assembly for each size. this allows minimum system field work. and system down time. . disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other...
https://www.bermad.com/wp-content/uploads/2016/05/IR-423-54-KX.pdf