cross-check solenoid's specifications with design requirements and solenoids/coils label. . pull and connect -wired cables, to the solenoid, according to electric diagram. ensure approved cables protection. confirm that the wires data meet specifications. note: energizing the solenoid coil when it is not
valve, with a latch solenoid. each electric command will cause the valve to alternate between fully open and closed. iom parts list b w hydraulic valve ( w/o spring) s w solenoid control filter w cock valve trouble-shooting . valve fails to open: check for sufficient inlet pressure, confirm solenoid is not...
https://www.bermad.com/wp-content/uploads/WW_710_IOM_English.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . cross-check solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it is not
the - -x- to react and the downstream pressure to stabilize. . after the pressure is stabilized lock the pilot nut. . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. iom ir- - -x trouble-shooting: symptoms cause remedy valve fails to open . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-120-55-X.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . cross-check solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it is not
nut. . after the pressure is stabilized, lock the pilot locking nut and open fully the downstream isolating valve. . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. iom ir- - -b trouble-shooting: symptoms cause remedy valve fails to open . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-120-55-b.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . cross-check solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it is not
the downstream pressure to stabilize. . after the pressure is stabilized lock the pilot nut. . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. iom ir- - trouble-shooting: symptoms cause remedy valve fails to open . cock valve ( ) position. . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-120-55.pdf
clock-wise to decrease it. allow the -xz to react and the upstream pressure to stabilize. iom ir- -xz . after the pressure is stabilized, lock the pilots locking nut and open fully the upstream isolating valve. trouble-shooting: symptoms cause remedy valve fails to open . cock valve ( ) is close. . not
sufficient inlet pressure. . not sufficient flow. . adjusting screws. . confirm cock valve is turn to auto. . check for sufficient inlet pressure. . create demand/flow, confirm pilot setting. . check that the prp adjusting screw. is not loose and that the psp adjusting screw is not too tighten. valve...
https://www.bermad.com/wp-content/uploads/2016/05/IR-123-XZ.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . cross-check solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it is not
the - -kx- to react and the downstream pressure to stabilize. . after the pressure is stabilized lock the pilot nut. . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. iom ir- - -kx trouble-shooting: symptoms cause remedy valve fails to open . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-55-KX.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . crosscheck solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it's not
after the pressure is stabilized, lock the pilot nut. . open fully the downstream isolating valve. iom ir- - -r . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. trouble-shooting: symptoms cause remedy valve fails to open . cock valve status. . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-55-R.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . cross-check solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it is not
the - -kb- to react and the downstream pressure to stabilize. . after the pressure is stabilized lock the pilot nut. . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. iom ir- - -kb trouble-shooting: symptoms cause remedy valve fails to open . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-420-55-bK.pdf
counter clock-wise to decrease it. allow the -r to react and the upstream pressure to stabilize. . after the pressure is stabilized, lock the pilots locking nut and open fully the upstream isolating valve. iom ir- trouble-shooting: symptoms cause remedy valve fails to open . cock valve is closed. . not
sufficient inlet pressure. . not sufficient flow. . adjusting screws. . confirm cock valve handle is parallel to the valve body. . check for sufficient inlet pressure. . create demand/flow, confirm pilot setting. . check that the prp adjusting screw. is not loose and that the psp adjusting screw is...
https://www.bermad.com/wp-content/uploads/2016/05/IR-423.pdf
carefully inspect/correct any damaged accessories, piping, tubing, or fittings. . cross-check solenoid specifications with design requirements and solenoid/coil label. . ensure approved cable protection. confirm that the wires data meet solenoid specifications. note: energizing the solenoid coil when it is not
decrease it. . after the pressure is stabilized, lock the pilot locking nut and open fully the upstream isolating valve . check valve solenoid control feature by de-energizing & energizing the solenoid to close & open the valve. iom ir- - -kx trouble-shooting: symptoms cause remedy valve fails to open . not...
https://www.bermad.com/wp-content/uploads/2016/05/IR-430-55-KX.pdf